Send Message
China Sodium Hypochlorite Generator manufacturer

Magnetic Fenton Package System For Food Processing Waste Water

Product Details:
Place of Origin: CHINA
Brand Name: Geemblue
Certification: ISO9001 CE
Model Number: FT-1WT
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Price: NEGOTIATION
Packaging Details: wooden case
Delivery Time: 60-80 work days
Payment Terms: L/C, T/T, Western Union
Supply Ability: 10 SET/MONTH

Detail Information

Model: FT-1WT Waste Water Treatment Amount: 10,000m3/day
COD Before Fenton: 150mg/L COD After Fenton: 50mg/L
PH: 6~9
Highlight:

Waste Water Fenton Package System

,

Magnetic Fenton Package System

Product Description

Magnetic Fenton Package System for Printing Waste water

 

 

Geemblue Magnetized Fenton Process

 

Use fixed-point removal method to oxidize COD , H202 consumption is extremely low, 40% cheaper than traditional Fenton.

 

Firstly magnetize the wastewater, change the arrangement position between pollutant molecules and water molecules, so that hydroxyl radicals can easily contact COD ,

 

Chemical process principle of Fenton

 

Under acidic conditions, H2O2 reacts with Fe2+ to produce hydroxyl radicals, which have strong oxidizing ability to quick oxidize and decompose the organic matter which is difficult to degrade.

Reaction equation: H202+Fe2+ →Fe3++OH-+·OH

Fe2+ is catalyst, H202 is oxidant, ·OH is hydroxyl radical, and the amount of hydroxyl radical generation is determined by Fe2+ and H202. Fenton’s key point is the oxidizing ability of hydroxyl radicals, which have two path after they are produced:


1. It does not contact pollutants and decomposes naturally, causing waste;
2. Contact to pollutants and oxidation.

 

Magnetic Fenton Package System For Food Processing Waste Water 0

 

Specifications:

 

 

Item CODcr (mg/L) Total Nitrogen SS (mg/L) Total Phosphorus PH
Inlet water ≤ 100 ≤ 15 ≤ 20 ≤ 2 6~9
Outlet water ≤ 50 ≤ 15 ≤ 20 ≤ 0.5 6~9


 

 