Product Details:
|
|
Place of Origin: | CHINA |
---|---|
Brand Name: | Geemblue |
Certification: | ISO9001 CE |
Model Number: | FT-4WT |
Payment & Shipping Terms:
|
|
Minimum Order Quantity: | 1 set |
Price: | NEGOTIATION |
Packaging Details: | wooden case |
Delivery Time: | 60-80 work days |
Payment Terms: | L/C, T/T, Western Union |
Supply Ability: | 10 SET/MONTH |
Detail Information |
|||
Model: | FT-4WT | Waste Water Treatment Amount: | 40,000m3/day |
---|---|---|---|
COD Before Fenton: | 150mg/L | COD After Fenton: | 50mg/L |
PH: | 6~9 | ||
High Light: | Magnetic Waste Water Treatment System,Magnetic Fenton Waste Water Treatment System,Fenton Waste Water Treatment System |
Product Description
Magnetic Fenton Package System for Printing Waste water
Geemblue Magnetized Fenton Process
Use fixed-point removal method to oxidize COD , H202 consumption is extremely low, 40% cheaper than traditional Fenton.
Firstly magnetize the wastewater, change the arrangement position between pollutant molecules and water molecules, so that hydroxyl radicals can easily contact COD ,
Geemblue “super cheap” Magnetic Fenton technology Advantage
Comprehensive Running Costs - Higher reaction conditions (reaction PH of 4-5), acid and alkali dosage are greatly reduced, the use of ferrous sulfate and hydrogen peroxide is greatly reduced too, and the overall pharmaceutical consumption is much lower.
Zero failure - It does not require the use of filler materials, there is no crystallization or filtration system to cause adsorption clogging or saturation problems, and there is no need for reflux or aeration in the reactor, which eliminates the root cause of sloughing and clogging.
Decrease in sludge volume - Sludge volume can be reduced by 30% compared to the fluidized bed fenton process.
Eradicate the problem of color return and mud floating - Reduced the use of Fe2SO4 and H2O2, residual Fe 3+ and H2O2 in the sewage is greatly reduced, solved the problem of iron ions return to the color and hydrogen peroxide decomposition to O2 with mud, etc., the water is clear and transparent.
Fully intelligent - The system is fully intelligent, minimizing the work pressure and technology dependence of on-site personnel.
Specifications:
Items | Fluidized bed fenton | Geemblue Magnetic fenton | |
Treatment condition | Initial PH | 3~4 | 4-5 |
Chemical consumption |
98% H2SO4 | 350mg/L | 250mg/L |
FeSO4 | 400mg/L | 300mg/L | |
27.5% H2O2 | 450mg/L | 220mg/L | |
30% NaOH | 800mg/L | 600mg/L | |
Filler | Require to use and replace regularly | No filler required, no Stiffening or clogging occur | |
Main Chemical cost | 0.315 USD/ton | 0.195 USD/ton | |
If use Jinchuan special chemical cost | / | 0.175 USD/ton | |
Effect | CODcr | < 50mg/L | < 50mg/L |
Civil construction | Reaction pool | Require degassing | No degassing require |